An industrial manifold connects multiple cylinders to one supply line so work does not stop when a cylinder empties. Harris industrial manifolds also include bulk and microbulk regulator manifolds. The Fastenal list for this category is manifold regulators (Model 3510 and one high-flow non-corrosive model) and four Model 647 panel-mount regulators.
How to choose
Flow need. Harris lists the Model 1030 bulk manifold at up to 10,000 scfh at 350 psi inlet.
Inlet pressure and gas. Manifold regulators have an inlet and delivery pressure range; match both.
Changeover. Harris's industrial manifold page lists automatic changeovers, fully automatic changeovers and protocol stations as categories.
Standards. Harris says its Model 1030 is designed to meet NFPA 99.
Regulator model. Harris lists Models 3500, 3510, 3540 and 9235 as its high-flow regulators for manifolds, and says the 1030 uses Model 3550-250 regulators.
Safety features. The Harris 1030 lists multiple pressure relief valves, quarter-turn valves, stainless steel diaphragms and dual regulators for redundancy.
Reading the part description
Term
Meaning
Example
3510-125 MANIFOLD LH
Model, top of delivery range in psi, thread hand
3510-125 MANIFOLD LH Pressure Regulator
RH / LH
Right or left-hand thread
3510-15 MANIFOLD LH Pressure Regulator
Non-Corrosive 0-500 psi
Delivery range, non-corrosive service
2-3/4" Non-Corrosive 0-500 psi High Flow Manifold Regulator
scfh
Standard cubic feet per hour
10,000 scfh
psig
Pressure above atmosphere, used on Harris inlet ratings
450 psig maximum inlet (Model 1030)
NFPA 99
Health care facilities gas standard cited by Harris
Designed to meet NFPA 99
Product families
Family
What it's for
Notes
Model 3510
High-flow manifold regulator
Five items on the list, in two categories
Model 647PM
Panel-mount pipeline regulator, non-corrosive service, 0-15 to 0-175 psi
Four items
High-flow non-corrosive manifold regulator
0-500 psi, 2-3/4 in. gauge
One item; confirm the model on the item page
Model 1030
Bulk and microbulk regulator manifold
Harris site, not on the Fastenal list
Model 3500, 3540, 9235
High-flow manifold regulators
3500 and 9235 are on the Pressure Regulation page; 3540 is not on the list
Seller tips
Ask the gas, flow rate and number of cylinders.
Check left-hand or right-hand threads for fuel gas.
The Fastenal list shows manifold and panel-mount regulators, not complete manifolds.
Harris says a pipeline regulator has no inlet limit other than the manufacturer's (500 psig for Models 247, 447 and 547); a station regulator with a C inlet is limited to 200 psig.
Mixing left-hand and right-hand versions is the most common ordering error on regulators.
Check inlet and delivery ranges together. Harris rates its 1030 bulk manifold for a 450 psig maximum inlet.